HyperWorks Solvers

PELAST

PELAST

Previous topic Next topic No expanding text in this topic  

PELAST

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

PELAST – Frequency-dependent Elastic Spring Property

Description

Defines the frequency dependent property values for a PELAS bulk data entry.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PELAST

PID

TKID

TGEID

TKNID

 

 

 

 

 

 

Field

Contents

PID

Property identification number. Must match with a PID of a PELAS bulk data entry.

No default (Integer > 0)

TKID

A TABLED# entry identification number that defines the force per unit displacement versus frequency relationship.

Default = 0 (Integer > 0)

TGEID

A TABLED# entry identification number that defines the element structural damping coefficient versus frequency relationship.

Default = 0 (Integer > 0)

TKNID

A TABLED# entry identification number that defines the nonlinear force versus displacement relationship.

The TKNID table is currently unused in nonlinear analysis and is ignored.

Default = 0 (Integer > 0)

Comments

1.Each PELAST entry must have a matching PELAS entry.
2.PELAST is ignored in all solution sequences except frequency response analysis. Nominal values from the PELAS entry are used in all the analyses except frequency response analysis.
3.If a particular TABLED ID is blank or 0, the corresponding nominal value from the PELAS entry will be used.
4.This card is represented as a property in HyperMesh.