HyperWorks Solvers

PFPANEL

PFPANEL

Previous topic Next topic No expanding text in this topic  

PFPANEL

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

I/O Options Entry

PFPANEL – Output Request for Acoustic Panel Participation

Description

The PFPANEL command can be used in the I/O Options section to request output of acoustic panel participation factors for all Modal Frequency Response subcases.

Format

PFPANEL (PANEL=setp, FREQUENCY=setf, outfile,peakout) = setdof/PEAKOUT

Examples

PFPANEL(PANEL=ALL,FREQUENCY=45)=12

PFPANEL(H3D, PEAKOUT)=56

PFPANEL(H3D, PEAKOUT)=PEAKOUT

PFPANEL(PUNCH)=32

Argument

Options

Description

setp

<ALL, NONE>

Default = NONE

ALL:

Output acoustic panel participation for all panels.

NONE:

Do not output acoustic panel participation.

 

setf

<ALL, SID>

Default = ALL

ALL:

Participation factors are processed for all excitation frequencies.

SID:

Participation factors are only processed for a set of excitation frequencies. SID refers to the ID of a SET of type FREQ.

 

outfile

<PUNCH, H3D>

Default = H3D

Panel participation can be exported either into a H3D file or a PUNCH file. Because of the large volume of data, it is recommended to export the panel participation data into a H3D file.

 

PEAKOUT

If PEAKOUT is present as an option inside the parentheses of the PFPANEL data, the filtered frequencies from the PEAKOUT data will be considered for output of panel participation.

 

setdof/
PEAKOUT

<SID/PEAKOUT>

Degrees-of-freedom for which the panel participation factors are to be processed. SID refers to the ID of a SET of type GRID. If PEAKOUT is specified instead of SID, the output will be considered at the filtered frequencies corresponding to the degree-of-freedom in the PEAKOUT card in the bulk section.

Comments

1.Output is to the H3D or PUNCH files only. The output of both PFMODE and PFPANEL must be either to an H3D file or to a PUNCH file. Both PFPANEL and PFMODE must have the same output option.
2.Acoustic panel participation factors are available in a coupled frequency response analysis (Modal Frequency Response only).
3.The FREQUENCY keyword can be used to select a subset of excitation frequencies available. The closest loading frequency will be chosen in this case.
4.Legacy format for the export of acoustic panel participation to H3D or PUNCH files: PFPANEL (OUTPUT=outfile)=setdof/PEAKOUT is also supported.

See Also: