HyperWorks Solvers

RSPEED

RSPEED

Previous topic Next topic Expand/collapse all hidden text  

RSPEED

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

RSPEED – Reference Rotor Speed Values

Description

This bulk data entry is used to specify a set of reference rotor speed values for asynchronous analysis in Rotor Dynamics.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

RSPEED

SID

S1

DS

NDS

 

 

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

RSPEED

25

1500

50

5

 

 

 

 

 

Argument

Options

Description

SID

<Integer > 0>

No default

Set identification number.

 

S1

<Real > 0.0>

No default

Specifies the first reference rotor speed in the set.

 

DS

<Real > 0.0>

No default

Specifies the increment in reference rotor speed. This value is added to each successive entry starting from the first entry (S1).

 

NDS

<Integer > 0>

Default = 1

Number of reference rotor speed increments.

Comments

1.The RSPEED bulk data entry is referenced by the SPEED field on the RGYRO bulk data entry. If an integer value is specified in the SPEED field, multiple reference rotor speeds specified in the RSPEED entry are used in asynchronous analysis.
2.In asynchronous frequency response analysis, if the RSPEED bulk data entry is referenced in RGYRO, only the first frequency is considered. In complex eigenvalue analysis, the full range specified by RSPEED is considered.
3.The following formula is used to populate the set of reference rotor speeds:

Where,

R1, R2, … RNDS represent the set of reference rotor speeds

S1 is the first reference rotor speed

DS is the reference rotor speed increment

NDS is the number of reference rotor speed increments

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function

The Input File