HyperWorks Solvers

/RWALL/THERM

/RWALL/THERM

Previous topic Next topic Expand/collapse all hidden text  

/RWALL/THERM

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Block Format Keyword

/RWALL/THERM - ALE Rigid Wall (Thermal Conductivity)

Description

Describes the ALE rigid wall.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

/RWALL/THERM/wall_ID

wall_title

 

Format only if node_ID = 0

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

node_ID

Slide

grnd_ID1

grnd_ID2

 

 

 

 

 

 

Dsearch

fric

diameter

 

 

 

 

XM

YM

ZM

 

 

 

 

XM1

YM1

ZM1

 

 

 

 

fct_IDT

 

FscaleT

R

 

 

 

 

 

Format only if node_ID > 0

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

node_ID

Slide

grnd_ID1

grnd_ID2

 

 

 

 

 

 

Dsearch

fric

diameter

 

 

 

 

Mass

VX0

VY0

VZ0

 

 

XM1

YM1

ZM1

 

 

 

 

Blank Format

fct_IDT

 

FscaleT

R

 

 

 

 

hmtoggle_plus1Flag Definition

Field

Contents

SI Unit Example

wall_ID

Rigid wall identifier

(Integer, maximum 10 digits)

 

wall_title

Rigid wall title

(Character, maximum 100 characters)

 

node_ID

Node identifier of the moving rigid wall

(Integer)

 

Slide

Sliding flag

(Integer)

= 0: Sliding

= 1: Tied

= 2: Sliding with friction

 

grnd_ID1

Node group defining slave nodes to be added to the rigid wall

(Integer)

 

grnd_ID2

Node group defining slave nodes to be deleted from the rigid wall

(Integer)

 

Dsearch

Distance for slave search

(Real)

symbol_m

fric

Friction

(Real)

 

diameter

Diameter

(Real)

symbol_m

XM

X coordinate of M, if node_ID = 0

(Real)

symbol_m

YM

Y coordinate of M, if node_ID = 0

(Real)

symbol_m

ZM

Z coordinate of M, if node_ID = 0

(Real)

symbol_m

Mass

Mass of the rigid wall, if node_ID > 0

(Real)

symbol_kg_unit

VX0

Initial velocity in X direction, if node_ID > 0

(Real)

fail_lad_SI_k

VY0

Initial velocity in Y direction, if node_ID > 0

(Real)

fail_lad_SI_k

VZ0

Initial velocity in Z direction, if node_ID > 0

(Real)

fail_lad_SI_k

XM1

X coordinate of M1

(Real)

symbol_m

YM1

Y coordinate of M1

(Real)

symbol_m

ZM1

Z coordinate of M1

(Real)

symbol_m

fct_IDT

Wall temperature function

(Integer)

 

FscaleT

Wall temperature scale factor

(Real)

fail_tab_temp

R

Thermal resistance R = d / K

(d = length, K = thermal conductivity)

(Real)

symbol_therm

hmtoggle_plus1Surface Input Type

Type

Description

PLANE

MM1 defines the normal direction

CYL

MM1 defines the axis of the cylinder

SPHER

M is the center of the sphere

PARAL

MM1 and MM2 define the parallelogram

hmtoggle_plus1Comments
1.An ALE rigid wall is defined by its normal symbol_n_line and either the coordinates of one point.
2.The first input to define the rigid wall is the coordinates of one point M or a node identifier node_ID in case of moving rigid wall.
3.Next input is the coordinate of a point M1 and eventually a point M2 (in case of a moving wall M1 and M2 have the same motion as node_ID).
4.The slave nodes can be defined as a list of nodes and/or as the nodes initially at a distance less than Dsearch from the wall.
5.Coordinates XM1, YM1, and ZM1 are read only if, Type = PLANE, CYL, or PARAL.
6.For parallelograms, the normal is defined using:

M or node identifier node_ID in case of a moving rigid wall