Bulk Data Entry
TABLED4 – Dynamic Load Tabular Function, Form 4
Description
Defines the coefficients of a power series for use in generating frequency-dependent and time-dependent dynamic loads. Also contains parametric data for use with the table.
Format
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
TABLED4 |
TID |
X1 |
X2 |
X3 |
X4 |
|
|
|
|
|
A0 |
A1 |
A2 |
A3 |
A4 |
A5 |
A6 |
A7 |
|
|
A8 |
… |
… |
… |
… |
… |
… |
… |
|
|
Field |
Contents |
---|---|
TID |
Table identification number. No default (Integer > 0) |
X# |
Table parameters. No default (Real; X2 ≠ 0.0; X3 < X4) |
A# |
Coefficients. No default (Real) |
1. | At least one continuation entry must be specified. |
2. | The end of the table is indicated by the existence of 'ENDT' in either of the two fields following the last entry. An error is detected if any continuations follow the entry containing the end-of-table flag 'ENDT'. |
3. | TABLED4 uses the algorithm: |
Where, x is input to the table, y is returned and N is the number of pairs. Whenever x < X3, use X3 for x; whenever x > X4, use X4 for x. There are N + 1 entries in the table. There are no error returns from this table look-up procedure.
4. | For frequency-dependent loads, x# is measured in cycles per unit time. |
5. | This card is represented as a loadcollector in HyperMesh. |
See Also: