TABLED4 – Dynamic Load Tabular Function, Form 4

Description

Defines the coefficients of a power series for use in generating frequency-dependent and time-dependent dynamic loads. Also contains parametric data for use with the table.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

TABLED4

TID

X1

X2

X3

X4

 

 

 

 

 

A0

A1

A2

A3

A4

A5

A6

A7

 

 

A8

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

TABLED4

28

0.0

1.0

0.0

100

 

 

 

 

 

2.91

-0.0329

6.51e-5

0.0

-3.4-7

ENDT

 

 

 

Field

Contents

TID

Table identification number.

No default (Integer > 0)

X#

Table parameters.

No default (Real; X2 ≠ 0.0; X3 < X4)

A#

Coefficients.

No default (Real)

Comments

1.At least one continuation entry must be specified.
2.The end of the table is indicated by the existence of 'ENDT' in either of the two fields following the last entry. An error is detected if any continuations follow the entry containing the end-of-table flag 'ENDT'.
3.TABLED4 uses the algorithm:

tabled4_eq

Where, x is input to the table, y is returned and N is the number of pairs. Whenever x < X3, use X3 for x; whenever x > X4, use X4 for x. There are N + 1 entries in the table. There are no error returns from this table look-up procedure.

4.For frequency-dependent loads, x# is measured in cycles per unit time.