TTERM - Termination Time for Geometric Nonlinear Analysis Subcase

Description

The TTERM command can be used in a geometric nonlinear subcase to define the termination time.

Format

TTERM = value

Argument

Description

value

Termination time for a geometric nonlinear subcase.

Default = 1.0 (Real)

Comments

1.TTERM is only allowed in geometric nonlinear subcases which are defined by an ANALYSIS = EXPDYN subcase entry.