HyperWorks Solvers

Velocity

Velocity

Previous topic Next topic No expanding text in this topic  

Velocity

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Introduction


The Nastran Punch (PCH) format file contains various supported output across multiple solution sequences. The output request initiation and corresponding parameters are controlled by the VELOCITY I/O Options and Subcase Information Entry.

The Velocity output format and information in the PCH file varies based on:

1.Solution Sequence
2.Requested corresponding output parameters

This document contains details about PCH output for various solution sequences, with corresponding output parameters (wherever applicable). Example: PCH output from actual models are illustrated with information about the various sections of the output.

Similar PCH format documents are available for all supported output variables (STRESS, STRAIN, and so on). See the .pch file for a full list of supported output variables in conjunction with PCH output format, along with a link to each detailed PCH format documents. For additional information about Output available in OptiStruct, refer to the Output section.

General Velocity PCH Format (File Specification)


The information in the PCH file varies depending on the requested output, however, some parts of the PCH file are common and the syntax is similar across most output data. The PCH file consists of data blocks, each containing corresponding information for the listed Subcase or the subsequent subset data (for example, eigenvalue or time step).

Each data block is printed with the following format.

Line 1 - $TITLE = This represents the Solver Name (OptiStruct) and the version Number (for example, 14.0.220).

Line 2 - $SUBTITLE =

Line 3 – $LABEL = This is the label of the Current Subcase (this is input in the model)

Line 4 - $<result type> This represents the type of results being printed in this data block.

Line 5 - $SUBCASE ID = This represents the ID of the subcase for which the results are printed in this data block. The $LABEL field in line 3 corresponds to this subcase.

Line 6 (Optional) - $<sorting> This is only printed if results of type <result type> can be further segregated based on additional filters (for example, additional filter: eigenvalue for result type: eigenvector).

Frequency Response Analysis


The supported Velocity output parameters for Frequency Response Analysis are:

General (Default)

For Velocity results with the default settings, for example if VELOCITY(PUNCH)=ALL/SID is used, the output is presented in the following format. For Frequency Response Analysis, the Velocity results are output for each loading frequency.

pch_velocity_freq_response

Sorted Output

The results can be sorted based on Frequency using the SORT1 (default) argument, as shown in the General section above. The SORT2 argument, which sorts results wherein grid/elements are grouped together (shown below). For Frequency Response Analysis, if grid SET is not specified, SORT1 is used, otherwise, SORT2 is used as default.

pch_velocity_freq_response_sorted_output

Output Form (form)

The format of the output can be selected using the form option. For PCH output, the REAL/IMAG (default) or PHASE arguments are available. The REAL/IMAG arguments provide output in the Rectangular format (shown in the Sorted Output section above). The PHASE argument provides output in the Polar format shown below.

pch_velocity_freq_response_output_form

Filtered Output (peakoutput)

Output can be filtered based on the loading frequencies at which specified result peaks occur. This can be controlled on the PEAKOUT Bulk Data Entry. The format for the PCH output is the same as those shown in previous sections. The output is just a smaller subset of loading frequencies.

Normal Velocity (type)

Normal velocity results for grid points on the surface of shell and solid elements are output. The NORMAL argument can be used to generate this output. Currently NORMAL velocity results are not available in the PCH file.

Random Response Analysis


The supported Velocity output parameters for Random Response Analysis are:

General (Default) or Random Output (random)

For Velocity results with the default settings, for example if VELOCITY(PUNCH)=ALL/SID is used, the output is presented in the following format. For Random Response Analysis, the Velocity results are basically Power Spectral Density values for each loading frequency. Only PSD output (via PSDF argument) is output to the PCH file. RMS (cumulative) or RMS (Over frequencies) are not printed to the PCH file. The RMS results are only printed to the H3D file.

pch_velocity_random_response

Linear Transient Analysis


The supported Velocity output parameters for Linear Transient Analysis are:

General (Default)

For Velocity results with the default settings, for example if VELOCITY(PUNCH)=ALL/SID is used, the output is presented in the following format. For Transient Response Analysis, the PCH file contains the Velocity values in SORT2 format by default, that is, the results for each Grid are grouped together.

pch_velocity_linear_transient

Sorted Output

The results can be sorted based on Grid points using the SORT2 (default) argument, as shown in the General section above. The SORT1 argument, which sorts results wherein Time steps are grouped together is shown below. Transient Response Results are different when compared to the Frequency Response Results as the default sorting for Transient Results is SORT2.

pch_velocity_linear_transient_sorted

Linear Transient Analysis by Fourier Transformation


The supported Velocity output parameters for Linear Transient Analysis by Fourier Transformation are:

General (Default)