In this tutorial you will learn how to:

Setup a model in HyperForm and identify any problems during the HyperForm interactive operation.

Step 1: FE-Model Setup

1.From Manufacturing Solution tab, select the HyperForm > FE Model tab > Model Setup tab.

See the HyperForm FE Model > Model Setup section for more information.

There is only a Modify cmf script option on this tab, not a Config file option.

hvvh_tut_8000_img1

Step 2: Basic import and export.

Identify any loss of data during import and export HyperForm operations.

1.From the Manufacturing Solution tab, select the HyperForm > FE Model tab > Basic IO tab.

hvvh_tut_8000_img2

2.For Solver type, select Incremental_Radioss.
3.For HW Version, select 2017.
4.Under Input decks, use the file browser icon, hwd_bmp00005, or the add file icon, add_file_icon, to select and open the DAD_radios_0000.rad file, located in
..\tutorials\hvvh\Manufacturing-solution\HF\Tut_01_AutoProcess_DAD.
5.For the Output directory field, use the open file icon, hwd_bmp00005, to select an output directory.
6.Click Import/Export.

Step 1 shows the import and export details and status (pass or fail) of the reference model file (selected above).

The last column displays information on the ASCII differences between the imported file and the HyperMesh exported file.  If there are no differences, it is shown as Pass, otherwise it is displayed as Fail.

The original model and the HyperForm exported models are run with the RADIOSS solver and the OUT file blocks are compared as shown in the status.

7.In the Messages window, the run details are displayed along with the log file location.

hvvh_tut_8000_img3

8.Click HTML Report to open an HTML report.

hvvh_tut_8000_img4

Step 3: Compare HyperForm Versions.

Compare the analysis decks exported in different versions of HyperForm.

1.From the Manufacturing Solution tab, select the HyperForm > FE Model tab > Compare HF Versions tab.

hvvh_tut_8000_img5

2.For File Type, select Incremental_Radioss.
3.For Current Version, select 2017.
4.For Reference Version, select 14.130.
5.Under Input decks, use the file browser icon, hwd_bmp00005, or the add file icon, add_file_icon, to select and open the DAD_radios_0000.rad file, located in
..\tutorials\hvvh\Manufacturing-solution\HF\Tut_01_AutoProcess_DAD.
6.For the Output directory field, use the open file icon, hwd_bmp00005, to select an output directory.
7.Click Import/Export.

The first table shows the import and export details and status (pass or fail) of the model file (selected above) in the current version.

The second table details the import and export time and status (pass or fail) of the model file (selected above) in the reference version.

The last column displays information on the ASCII differences between the exported files in the current and reference versions of HyperMesh.  If there is no difference, it is shown as Pass, otherwise it is displayed as Fail.

8.In the Messages window, the run details are displayed along with the log file location.
9.Click HTML Report to open an HTML report.

hvvh_tut_8000_img6

Step 4: Solver check run for HyperXtrude.

In this step, you will perform a check run on a solver deck (Incremental_Radioss or Radioss_one_step), and OUT files comparison of a solver written result file after the check run.

Three options are available for the solver check run:

Two OUT files generated from the solver run can be compared.
The current solver run OUT file can be compared with the reference OUT file.
Two OUT files generated from the same solver deck using two different solver versions can be compared.
1.From the Manufacturing Solution tab, select the HyperForm > Solution tab > Check run tab.
2.See the Check Run section of the Solution Tab topic for more information on the tab's options.

Step 5: Compare results from different solver versions (HyperForm).

In this step, you will perform solver version result comparison for HyperForm solver results for any given model.  If the result files are not available, the solver run can be performed in the background, and the results generated are used in the result comparison.  Results from Radioss_onestep or Radioss_incremental can be compared.

1.From the Manufacturing Solution tab, select the HyperXtrude/HyperModel > Solution tab > Solver version result comparison tab.
2.See the Solver version result comparison section of the Solution Tab topic for more information on the tab's options.

Step 6: Compare results from a HyperForm solver across different HyperView versions.

Compare result from a solver across two HyperView versions (For RADIOSS and H3D).

 

1.From the Manufacturing Solution tab, select the HyperForm > Result tab > Solver result comparison HV versions tab.
2.See the Solver result comparison HV versions section of the Result Tab topic for more information on the tab's options.

Step 7: Compare results from a HyperForm solver across two different HyperGraph versions.

Compare result from a solver across two HyperGraph versions.

 

1.From the Manufacturing Solution tab, select the HyperForm > Result tab > Result comparison HG versions tab.