HyperWorks Solvers

BNDFIX

BNDFIX

Previous topic Next topic Expand/collapse all hidden text  

BNDFIX

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

BNDFIX – Boundary Degrees-of-Freedom of a Superelement Assembly

Description

Defines the degrees-of-freedom to be fixed during DMIG generation using CMSMETH card.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

BNDFIX

GID1

IC1

GID2

IC2

GID3

IC3

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

BNDFIX

1220

12345

 

 

 

 

 

 

 

Field

Contents

GIDi

Grid of scalar point identification numbers.

No default (Integer > 0)

ICi

Component numbers.

No default (Integer > 0)

Comments

1.BNDFIX and BSET are equivalent.
2.ASET, BNDFIX and BNDFREE; all three are not allowed in the same deck.
3.If BNDFREE and ASET are present, the DOFs associated with ASET would be in BNDFIX; except the DOF assigned to BNDFREE.
4.If BNDFIX and ASET are present, the DOFs associated with ASET would be in BNDFREE; except the DOF assigned to BNDFIX.

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

The Input File