HyperWorks Solvers

BNDFIX1

BNDFIX1

Previous topic Next topic Expand/collapse all hidden text  

BNDFIX1

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

BNDFIX1 – Fixed Boundary Degrees-of-Freedom of a Superelement Assembly

Description

Defines the fixed (B-set) degrees-of-freedom to be fixed during DMIG generation using CMSMETH card.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

BNDFIX1

C

GID1

GID2

GID3

GID4

"thru"

GID6

GID7

 

 

GID8

GID9

etc.

 

 

 

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

BNDFIX1

12345

1220

1221

THRU

1229

 

 

 

 

Field

Contents

C

Component numbers.

No default (Integer > 0 or blank). Zero or blank for SPOINT and any unique combination of integers 1 through 6 for grid points with no embedded blanks.

GIDi

Grid of scalar point identification numbers.

No default (Integer > 0)

THRU

Keyword to allow a range of GID. THRU can be in any field.

Comments

1.BNDFIX1 and BSET1 are equivalent.
2.The combination of the three ASET/ASET1, BNDFIX/BNDFIX1 and BNDFREE/BNDFRE1 are not allowed together in the same input data.
3.If BNDFREE/BNDFRE1 and ASET/ASET1 are present, the DOFs associated with ASET will be in the B-set; except the DOF assigned to BNDFREE which will be in the C-set.
4.If BNDFIX/BNDFIX1 and ASET/ASET1 are present, the DOFs associated with ASET would be in C-set; except the DOF assigned to BNDFIX which will be in the B-set.
5.Multiple “THRU” sequences can be used on a single card, and can span across continuation lines.
6.If the "THRU" comment is used, G1 and G2 must exist, but the grid points between G1 and G2 are not required to exist.

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

The Input File