HyperWorks Solvers

CGASK16

CGASK16

Previous topic Next topic Expand/collapse all hidden text  

CGASK16

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

CGASK16 – Six-sided Solid Gasket Element with Sixteen Grid Nodes

Description

Defining the connections of the GASK16 solid gasket element.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

CGASK16

EID

PID

G1

G2

G3

G4

G5

G6

 

 

G7

G8

G9

G10

G11

G12

G13

G14

 

 

G15

G16

 

 

 

 

 

 

 

 

CORDM

CID

 

 

 

 

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

CGASK16

71

4

3

4

5

6

7

8

 

 

9

10

11

12

13

14

15

16

 

 

17

18

 

 

 

 

 

 

 

Field

Contents

EID

Unique element identification number.

No default (Integer > 0)

PID

Identification number of a PGASK property entry.

Default = EID (Integer > 0)

G#

Grid point identification number of connection points.

No default (Integer > 0)

CORDM

Flag indicating that the following field references the material coordinate system.

CID

Identification number of the material coordinate system.

Default = 0 (Integer ≥ -1)

Comments

1.Corner grid points G1, …, G4 must be given in consecutive order at the bottom face of the gasket element. Corner grid points G5, …, G8 must be on the top face with G5 opposite G1, G6 opposite G2, and so on.

Edge grid points G9, …, G12 must be given in consecutive order at the bottom face of the gasket element. Edge grid points G13, …, G16 must be on the top face with G13 opposite G9, G14 opposite G10, and so on.

cgask16

2.If the user-defined node numbering on the bottom and top faces is reversed as compared to the sequence shown above, the nodes are renumbered to produce right-handed orientation of numbering. This is accomplished by swapping nodes G1 with G3, and G5 with G7. In such cases, the element local coordinate system will be built on the renumbered node sequence.
3.The element coordinate system for the CGASK16 element is defined below.

The local 3-direction (the gasket material thickness direction in default) is defined as the simple average of the unit normal directions on the top and bottom surfaces of the element. After the local 3-direction is defined, a local 1-2 plane is generated accordingly.

Then, the local 1-direction and 2-direction are defined as follows: Project the basic x-axis onto the local 1-2 plane, and set it to be the default local 1-direction. If the basic x-axis is within 0.1° difference as the local 3-direction, project the basic z-axis onto the local 1-2 plane and set it to be the local 1-direction. The local 2-direction is determined then.

4.The gasket material coordinate system is the same as the element coordinate system in default and can be defined as a prescribed system through PGASK entry.
5.This card is represented as a gask16 element in HyperMesh.

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function

The Input File