HyperWorks Solvers

CHACAB

CHACAB

Previous topic Next topic Expand/collapse all hidden text  

CHACAB

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

CHACAB – Acoustic Absorber Element Connection

Description

Defines the acoustic absorber element in coupled fluid-structural analysis.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

CHACAB

EID

PID

G1

G2

G3

G4

G5

G6

 

 

G7

G8

G9

G10

G11

G12

 

 

 

 

 

 

G17

G18

G19

G20

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

CHACAB

11

9

221

222

225

226

227

229

 

 

321

323

 

 

 

 

 

 

 

Field

Contents

EID

Unique element identification number.

No default (Integer > 0)

PID

Identification number of a PACABS property entry.

Default = EID (Integer > 0)

Gi

Grid point identification numbers of connection points.

Default = blank (Integer > 0)

Comments

1.Element identification numbers should be unique with respect to all other element identification numbers.
2.Grids G1 through G4 should be provided consecutively about one quadrilateral face. G5 through G8 should be provided on the opposite face with G5 opposite G1, G6 opposite G2, and so on.
3.The grids G9 to G20 are optional. If any edge connection point is blank or set to zero, the element formulations are modified to provide proper results for reduced number of connections. Corner grids cannot be deleted. The second continuation line is not mandatory. Additionally, it recommended that the edge points should be present within the mid-third of the edge.

See Also:

Coupled Frequency Response Analysis of Fluid-Structure Models

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function

The Input File