/EIG - Eigen Modes and Static Modes Computation

Description

Defines the eigen modes and static modes computation for flexible bodies.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

/EIG/eig_ID/unit_ID

eig_title

grnd_ID

grnd_bc

Trarot

Ifile

 

 

 

 

 

 

Nmod

Inorm

Cutfreq

Freqmin

 

 

 

 

Nbloc

Incv

Niter

Ipri

Tol

 

 

 

 

Filename

hmtoggle_plus1Flag Definition

Field

Contents

SI Unit Example

eig_ID

Mode identifier

(Integer, maximum 10 digits)

 

unit_ID

Optional unit identifier

(Integer, maximum 10 digits)

 

eig_title

Mode title

(Character, maximum 100 characters)

 

grnd_ID

Node group to which the modes will be computed

(Integer)

= 0: modes are computed for the entire structure.

 

grnd_bc

Node group to which specific eigen modes are applied (Comment 3)

(Integer)

= 0: Free eigen modes are computed

0: The node group defines a set of interface nodes

 

Trarot

Codes for translations and rotations

(6 Booleans)

 

Ifile

Additional modes file flag (Comment 5)

(Integer)

 

Nmod

Maximum number of modes to be computed

Default = 100  (Integer)

 

Inorm

Eigenvector normalization method flag

Default = 0  (Integer)

= 0: eignvectors are normalized to the unit value of the generalized mass.

= 1: eigenvectors are normalized to the unit value of the largest displacement in the analysis set.

 

Cutfreq

Maximum eigen frequency

(Real)

= 0: All Nmod eigen modes whose frequencies are higher than Freqmin are computed.

0: At most Nmod eigen modes whose frequencies lie in the frequency range Freqmin, Cutfreq are computed.

symbol_Hz

Freqmin

Minimum eigen frequency (Comment 7)

Default = 0.001 Hz  (Real)

symbol_Hz

Nbloc

Number of eigen modes per block (Comment 9)

(Integer)

0: The modes are computed per block of Nbloc eigen modes.

= 0: All eigen modes are computed at the same time.

 

Incv

Factor to obtain the number of Lanczos basis vectors to use throughout the computation (Comment 10)

Default = 2  (Integer)

 

Niter

Maximum number of Arnoldi iterations

Default = 300  (Integer)

 

Ipri

Printout level for ARPACK

Default = 0  (Integer)

 

Tol

Relative accuracy to which eigen values are to be computed

Default = 0.0  (Real)

= 0: The tolerance for eigenvalues accuracy is set to machine precision.

 

Filename

Additional modes file name

(Character, maximum 100 characters)

 

hmtoggle_plus1Comments
1.This functionality is implemented for the purpose of the generation of flexible bodies. For detailed normal modes analysis of a model the use of the Bulk Data Format is strongly recommended.
2.The use of the implicit option /IMPL/LINEAR in the RADIOSS Engine is required to compute normal modes.
3.Boundary condition corresponding to the codes for translations and rotations are added to these nodes for the computation of eigen modes. Static modes, one for each additional blocked DOF, are computed.

A static mode corresponds to the static response of the structure, all DOF of the set of interface nodes concerned by additional boundary conditions being blocked; except one taking the one value.

4.The codes for translations and rotations follow the same rule as for the /BCS option.
5.If Ifile ≠ 0: An additional file is provided containing pre-computed modes from a normal modes analysis, either experimental or numerical. These modes are used to reduce the dimension of the space in which eigenvalues are sought and thus enhance efficiency.

If Ifile = 1, the additional file is given in a format defined in External Modes File.

6.Multi-level condensation is no longer supported.
7.The default (if set blank or zero) for Freqmin is 0.001 Hz. If a value other than zero is entered, that value defines a frequency in the unit system set for /EIG. The capability of computing rigid body modes is not fully implemented. It is recommended to either sufficiently constrain the model or to select a value for Freqmin that is high enough to eliminate all rigid body modes.
8.Eigen modes are computed using ARPACK software (R. Lehoucq, K. Maschhoff, D. Sorensen, C. Yang).

clip0033

9.Better precision is achieved when only a small number of eigen modes are computed simultaneously.
10.The number of Lanczos basis vectors to use through the course of the computation is given from the number of required eigenvalues per block (or total if Nbloc = 0) by the formula:

NLanczos vectors = Nrequired eigenvalues * Incv.