Bulk Data Entry

ERPPNL – Panel Definition for Equivalent Radiated Power Output

Description

Defines one or more sets of elements as panels for equivalent radiated power output for a frequency response analysis of a coupled fluid-structural model.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

ERPPNL

NAME1

SID1

NAME2

SID2

NAME3

SID3

NAME4

SID4

 

 

NAME5

SID5

 

 

 

 

 

 

 

Field

Contents

NAME#

Panel label.

No default (Character string)

SID#

Set identification number for a set of elements.

No default (Integer > 0)