HyperWorks Solvers

FREQ1

FREQ1

Previous topic Next topic Expand/collapse all hidden text  

FREQ1

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

FREQ1 – Frequency List, Alternate Form 1

Description

Defines a set of frequencies to be used in the solution of frequency response problems by specification of a starting frequency, frequency increment, and the number of increments desired.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

FREQ1

SID

F1

DF

NDF

 

 

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

FREQ1

6

2.9

0.5

13

 

 

 

 

 

Field

Contents

SID

Set identification number.

No default (Integer > 0)

F1

First frequency in set.

No default (Real > 0)

DF

Frequency increment.

No default (Real > 0.0)

NDF

Number of frequency increments.

Default = 1 (Integer > 0)

Comments

1.FREQ1 entries must be selected with the I/O Options or Subcase Information command FREQUENCY = SID.
2.The units for F1 and DF are cycles per unit time.
3.The frequencies defined by this entry are given by fi = F1 + DF * (i -1)

where i = 1 to (NDF + 1).

4.All FREQi entries with the same set identification numbers will be used. Duplicate frequencies will be ignored. fN and fN-1 are considered duplicated if:

freq_eq

where, DFREQ is a user parameter with a default of 10-5 * fMAX , and fMIN are the maximum and minimum excitation frequencies of the combined FREQi entries.

5.This card is represented as a loadcollector in HyperMesh.

See Also:

Frequency Response Analysis

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function

The Input File