HyperWorks Solvers

MBPTCV

MBPTCV

Previous topic Next topic Expand/collapse all hidden text  

MBPTCV

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

MBPTCV – Multi-body Point to Curve Constraint

Description

Defines a Point to Parametric Curve Constraint.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MBPTCV

JID

GID

PCID

G3

V0

 

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MBPTCV

1

21

2

25

0

 

 

 

 

Field

Contents

JID

Joint identification number.

No default (Integer > 0)

GID

Grid identification number corresponding to the point which is sliding on a curve.

No default (Integer > 0)

PCID

Parametric curve (MBPCRV) identification number.

No default (Integer > 0)

G3

This grid specifies the guess for the initial contact point on the curve.

Default is GID (Integer > 0)

V0

Specifies the initial sliding velocity of the contact point, as measured by an observer on the curve, placed at the contact point.

Default = 0.0 (Real)

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

The Input File