Subcase Information Entry
MODEWEIGHT - Optimization Parameter
Description
The MODEWEIGHT command can be used in the Subcase Information section to define a multiplier for computed eigenvalues that are to be used in the calculation of the "weighted reciprocal eigenvalue" and "combined compliance index" optimization responses.
Format
MODEWEIGHT (mode) = weight
Argument |
Description |
mode |
Mode number. If a mode number is not provided, OptiStruct will terminate with an error. No default (0 < Integer < highest calculated mode) |
weight |
The multiplier to be used for the corresponding mode in the calculation of "weighted reciprocal eigenvalue" or "combined compliance index." Default = 1.0 (Real) |
1. | Modes for which there is no MODEWEIGHT definition are not included in the calculation of the "weighted reciprocal eigenvalue" and "combined compliance index" optimization responses. |
2. | Refer to Responses in the User's Guide for more information on "weighted reciprocal eigenvalue" and "combined compliance index" optimization response calculations. |
3. | MODEWEIGHT is only used in conjunction with DRESP1, RTYPE = WFREQ, COMB. |
4. | If MODEWEIGHT is not defined, but a DRESP1 with RTYPE = WCOMP exists, the following default is applied: |
• | MODEWEIGHT (1) = 1.0 in most cases for topology optimization. |
• | MODEWEIGHT (7) = 1.0 if SPC is not defined for the subcase, EIGRL does not define a V1 > 0.0, and it is solving for more than 6 modes or all modes below an upper bound. |
5. | This entry is represented as an optimization response in HyperMesh. |
See Also: