HyperWorks Solvers

NSGE1

NSGE1

Previous topic Next topic Expand/collapse all hidden text  

NSGE1

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

NSGE1 – Non-structural Material Damping, Alternate Form 1

Description

Defines non-structural material damping for a list of elements or properties.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

NSGE1

SID

TYPE

VALUE

ID

ID

ID

ID

ID

 

 

ID

ID

ID

etc

 

 

 

 

 

hmtoggle_plus1Example 1

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

NSGE1

2

ELEMENT

0.04

2

5

 

 

 

 

hmtoggle_plus1Alternate Format and Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

NSGE1

SID

TYPE

VALUE

ID

THRU

ID

 

 

 

NSGE1

4

PSHELL

0.04

8

THRU

11

 

 

 

Field

Contents

SID

Non-structural material damping set identification number.

No default (Integer > 0)

TYPE

This can be one of the properties PSHELL, PCOMP, PBAR, PBARL, PBEAM, PBEAML, PROD, CONROD, PSHEAR, or PTUBE, in which case the list of IDs will refer to properties of the stated type, or it can be ELEMENT, in which case the list is of individual element IDs of elements with the specified non-structural material damping value. It can also be of type ELSET, in which case, it is an element SET ID.

When set to PSOLID, fluid elements are currently not supported.

No default (PSOLID, PSHELL, PCOMP, PBAR, PBARL, PBEAM, PBEAML, PROD, CONROD, PSHEAR, PTUBE, ELEMENT, or ELSET).

ID

Property, Element ID, or Element Set ID depending on the TYPE definition.

No default (Integer > 0, or "THRU")

VALUE

Non-structural material damping value.

No default (Real)

Comments

1.Non-structural material damping in this format must be selected by the NSGE Subcase Information selector.
2.Optimization is currently not supported for non-structural damping.

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function

The Input File