HyperWorks Solvers

PTUBE

PTUBE

Previous topic Next topic Expand/collapse all hidden text  

PTUBE

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

PTUBE – Tube Property

Description

PTUBE defines the properties of a thin-walled cylindrical tube element, referenced by a CTUBE entry.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PTUBE

PID

MID

OD

T

NSM

OD2

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PTUBE

2

6

6.29

0.25

 

 

 

 

 

Field

Contents

PID

Unique property identification number.

(Integer > 0)

MID

Material identification number.

(Integer > 0)

OD

Outside diameter of tube.

(Real > 0.0)

T

Thickness of tube.

If T is zero, a solid circular rod is assumed.

(Real; T < ½ OD)

NSM

Nonstructural mass per unit length.

(Real)

OD2

Diameter of tube at second grid point – G2 on CTUBE entry. See comment 2.

Default = OD (OD or blank)

Comments

1.For structural problems, PTUBE entries may only reference MAT1 material entries.
2.Tapered tubes are not allowed.
3.PTUBE data is converted to PROD data as it is read. CTUBE data is converted to CROD data.
4.This card is represented as a property in HyperMesh.

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function

The Input File