Bulk Data Entry
PTUBE – Tube Property
Description
PTUBE defines the properties of a thin-walled cylindrical tube element, referenced by a CTUBE entry.
Format
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
PTUBE |
PID |
MID |
OD |
T |
NSM |
OD2 |
|
|
|
|
Field |
Contents |
PID |
Unique property identification number. (Integer > 0) |
MID |
Material identification number. (Integer > 0) |
OD |
Outside diameter of tube. (Real > 0.0) |
T |
Thickness of tube. If T is zero, a solid circular rod is assumed. (Real; T < ½ OD) |
NSM |
Nonstructural mass per unit length. (Real) |
OD2 |
Diameter of tube at second grid point – G2 on CTUBE entry. See comment 2. Default = OD (OD or blank) |
1. | For structural problems, PTUBE entries may only reference MAT1 material entries. |
2. | Tapered tubes are not allowed. |
4. | This card is represented as a property in HyperMesh. |
See Also: