SLOAD – Static Scalar Load

Description

Defines concentrated static loads on scalar, grid or fluid points.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

SLOAD

SID

S1

F1

S2

F2

S3

F3

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

SLOAD

21

3

4.5

4

29.0

 

 

 

 

Field

Contents

SID

Load set identification number.

No default (Integer > 0)

S#

A scalar, grid or fluid point identification number.

No default (Integer > 0)

F#

Load magnitude.

No default (Real)

Comments

1.SLOAD may be referenced as the EXCITEID on an ACSRCE bulk data entry.
2.Up to three loads may be defined on a single entry.