HyperWorks Solvers

TABLEM4

TABLEM4

Previous topic Next topic Expand/collapse all hidden text  

TABLEM4

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

TABLEM4 – Material Property Table, Form 4

Description

Defines coefficients of a power series for use in generating temperature-dependent material properties. Also contains parametric data for use with the table.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

TABLEM4

TID

X1

X2

X3

X4

 

 

 

 

 

A0

A1

A2

A3

A4

A5

-etc.-

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

TABLEM4

28

0.0

1.0

0.0

100.

 

 

 

 

 

2.91

-0.0329

6.51-5

0.0

-3.4-7

ENDT

 

 

 

Field

Contents

TID

Table identification number.

(Integer > 0)

Xi

Table parameters.

(Real; X2 ≠ 0.0; X3 < X4)

Ai

Coefficients.

(Real)

Comments

1.At least one continuation entry must be specified.
2.The end of the table is indicated by the existence of "ENDT" in the field following the last entry. An error is detected if any continuations follow the entry containing the end-of-table flag "ENDT".
3.TABLEM4 uses the algorithm:

tablem4eq

Where, x is input to the table, y is returned, and z is supplied from the MATi entry. Whenever x < X3, use X3 for x; whenever x > X4, use X4 for x. There are N + 1 entries in the table. There are no error returns from this table look-up procedure.

4.This card is represented as a loadcollector in HyperMesh.

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function

The Input File