Bulk Data Entry
TABLEM4 – Material Property Table, Form 4
Description
Defines coefficients of a power series for use in generating temperature-dependent material properties. Also contains parametric data for use with the table.
Format
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
TABLEM4 |
TID |
X1 |
X2 |
X3 |
X4 |
|
|
|
|
|
A0 |
A1 |
A2 |
A3 |
A4 |
A5 |
-etc.- |
|
|
|
Field |
Contents |
TID |
Table identification number. (Integer > 0) |
Xi |
Table parameters. (Real; X2 ≠ 0.0; X3 < X4) |
Ai |
Coefficients. (Real) |
1. | At least one continuation entry must be specified. |
2. | The end of the table is indicated by the existence of "ENDT" in the field following the last entry. An error is detected if any continuations follow the entry containing the end-of-table flag "ENDT". |
3. | TABLEM4 uses the algorithm: |
Where, x is input to the table, y is returned, and z is supplied from the MATi entry. Whenever x < X3, use X3 for x; whenever x > X4, use X4 for x. There are N + 1 entries in the table. There are no error returns from this table look-up procedure.
4. | This card is represented as a loadcollector in HyperMesh. |
See Also: