TEMPD – Grid Point Temperature Field Default
Description
Defines a temperature value for all grid points of the structural model that have not been given a temperature on a TEMP entry.
Format
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
TEMPD |
SID |
T |
SID |
T |
SID |
T |
SID |
T |
|
|
Field |
Contents |
SID |
LOAD set identification. (Integer > 0) |
T |
Default temperature value. From one to four default temperatures may be defined on a single entry. (Real) |
1. | Temperature sets may be selected for use in a subcase by the TEMPERATURE(LOAD) or TEMPERATURE(BOTH) subcase information entry. For transient heat transfer analysis, the temperature set can be selected by IC subcase information entry to specify initial condition. |
2. | This card is represented as a loadcollector in HyperMesh. |
See Also: