TSTRU - Temperature Set ID for Structural Analysis
The TSTRU command can be used in the Subcase Information section to assign a temperature set identification number to the resulting nodal temperatures of a steady-state heat transfer analysis or the last time step of a transient heat transfer analysis.
TSTRU = option
Argument |
Options |
Description |
|
option |
< SID > Default = Subcase ID |
SID: |
This is a temperature set identification number. It may be referenced from a static analysis subcase, in which case the resulting nodal temperatures of a steady-state heat transfer analysis or the last time step of a transient heat transfer analysis are considered as applied loads for the static analysis. |
Comments
1. | TSTRU is only valid in a heat transfer subcase. |
2. | If TSTRU does not explicitly appear in a heat transfer subcase, the Subcase ID is used as the default. |
3. | A temperature set from a heat transfer analysis will override any temperature set defined by the bulk data entries TEMP or TEMPD. |
See Also: