Bulk Data Entry

DTI,SPECSEL – Response Spectra Input Correlation Table

Description

Correlates spectra lines specified on TABLED1 entries with damping values.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DTI

SPECSEL

ID

 

TYPE

TID1

DAMP1

TID2

DAMP2

 

 

TID3

DAMP3

 

 

 

 

 

 

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DTI

SPECSEL

99

 

A

2

0.0

3

0.02

 

 

4

0.04

 

 

 

 

 

 

 

Field

Contents

ID

DTI,SPECSEL identification number. All DTI,SPECSEL cards must have unique identification numbers.

No default (Integer > 0)

TYPE

Type of spectrum. Can be either acceleration (A), velocity (V) or displacement (D).

No default (A, V, D)

TID#

A TABLED1 entry identification number that defines a line of the spectrum.

No default (Integer > 0)

DAMP#

Damping value assigned to TID#.

No default (Real)

Comments

1.The TID#, DAMP# pairs list the TABLED1 entry, which defines a line of the spectrum and the damping value assigned to it. The damping value is in the units of fraction of critical damping.
2.If only a single TID# and DAMP# pair is specified, the reference curves for different damping values will not be extrapolated from the specified values.
3.Refer to Response Spectrum Analysis in the User’s Guide for more details.