HyperWorks Solvers

MATF3

MATF3

Previous topic Next topic Expand/collapse all hidden text  

MATF3

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

MATF3 – Orthotropic Material Frequency Dependence

Description

Specifies frequency-dependent material properties on MAT3 data entry fields via TABLEDi entries.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATF3

MID

T(EX)

T(ETH)

T(EZ)

T(NUXTH)

T(NUTHZ)

T(NUZX)

T(RHO)

 

 

 

 

T(GZX)

T(AX)

T(ATH)

T(AZ)

 

T(GE)

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATF3

17

32

 

 

 

 

 

19

 

 

 

 

 

 

 

 

 

52

 

Field

Contents

MID

Material property identification number that matches the identification number on the MAT3 entry.

(Integer > 0)

T(EX)
T(ETH)
T(EZ)

TABLEDi entry identification numbers for Young’s moduli in the x, θ and z directions.

Default = blank (Integer > 0 or blank)

T(EX)
T(ETH)
T(EZ)

TABLEDi entry identification numbers for Poisson’s ratios in the xθ, θz and zx directions.

Default = blank (Integer > 0 or blank)

T(RHO)

A TABLEDi entry identification number for the mass density.

Default = blank (Integer > 0 or blank)

T(GZX)

A TABLEDi entry identification number for the shear modulus.

Default = blank (Integer > 0 or blank)

T(AX)
T(ATH)
T(AZ)

TABLEDi entry identification numbers for thermal expansion coefficients in the x, θ and z directions.

Default = blank (Integer or blank)

T(GE)

A TABLEDi entry identification number for the damping coefficient.

Default = blank (Integer > 0 or blank)

Comments

1.Fields 3, 4, and so on of this entry correspond, field-by-field, to fields 3, 4, and so on of the MAT3 entry referenced in field 2. The value in a particular field of the MAT3 entry is replaced or modified by the table referenced in the corresponding field of this entry. In the example shown, EX is modified; TABLEDi 32, RHO is modified by TABLEDi 19; and GE is modified by TABLEDi 52.
2.Blank or zero entries mean that there is no frequency dependence of the field on the MAT3 entry. Any quantity modified by this entry must have a value on the MAT3 entry.
3.In Modal Frequency Response Analysis, the frequency-dependency is only used in the frequency response part of the solution, not in the modal analysis part of the solution.
4.This card is represented as a material in HyperMesh.

See Also:

Frequency Response Analysis

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function

The Input File