PBARX – Optional BAR Property Extension for Geometric Nonlinear Analysis

Description

Defines additional BAR properties for geometric nonlinear analysis.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PBARX

PID

ISMSTR

ISTRAIN

DM

DB

 

 

 

 

 

Field

Contents

PID

Property identification number of the associated PBAR or PBARL card. See comment 1.

No default (Integer > 0)

ISMSTR

Small strain formulation flag.

Default = 2 (Integer = 1 or 2)

1 - Small strain from time =0. If the small strain option is activated (ISMSTR = 1), the strain and stress are engineering strain and stress; otherwise they are true strain and stress.

2 - Full geometric nonlinearity

ISTRAIN

Shear in beam formulation flag.

Default = ON (ON or OFF)

DM

Beam membrane damping.

Default = 0.0 (Real > 0)

DB

Beam bending damping.

Default = 0.01 (Real > 0)

Comments

1.The property identification number must be that of an existing PBAR bulk data entry. Only one PBARX property extension can be associated with a particular PBAR.
2.PBARX is only applied in geometric nonlinear analysis subcases which are defined by ANALYSIS = EXPDYN. It is ignored for all other subcases.
3.This card is represented as an extension to a PBAR property in HyperMesh.