Bulk Data Entry
RLOAD1 – Frequency Response Dynamic Load, Form1
Description
Defines a frequency-dependent dynamic load of the form:
for use in frequency response problems. RLOAD1 (Form 1) can be used when the frequency-dependent dynamic load input is available in real/imaginary number format.
Format
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
RLOAD1 |
SID |
EXCITEID |
DELAY |
DPHASE |
TC |
TD |
TYPE |
|
|
|
Field |
Contents |
SID |
Set identification number. Must be unique for all RLOAD1 and RLOAD2 entries. No default (Integer > 0) |
EXCITEID |
Identification number of the DAREA, SPCD, FORCEx, MOMENTx, PLOADx, RFORCE, ACCEL, ACCEL1, ACCEL2 or GRAV entry set that defines A. No default (Integer > 0) |
DELAY |
Defines time delay Default = 0 (Integer > 0, or Real) |
DPHASE |
Defines phase Default = 0 (Integer > 0, or Real) |
TC |
Set identification number of the TABLED1, TABLED2, TABLED3 or TABLED4 entry that gives Default = 0 if TD is non-zero (Integer > 0) |
TD |
Set identification number of the TABLED1, TABLED2, TABLED3 or TABLED4 entry that gives Default = 0 if TC is non-zero (Integer > 0) |
TYPE |
Identifies the type of the dynamic excitation. Default = 0 (See comment 4) |
1. | Dynamic load sets must be selected in the I/O Options or Subcase Information sections with the command DLOAD = SID. |
2. | If any DELAY, DPHASE, TC, or TD fields are blank or zero, the corresponding ![]() ![]() ![]() ![]() |
3. | RLOAD1 loads may be combined with RLOAD2 loads only by specification on a DLOAD entry. This means that the SID on a RLOAD1 entry must not be the same as that on a RLOAD2 entry. |
4. | Valid entries for the TYPE field are listed alongside a description of the dynamic excitation which they invoke. |
Type |
Description |
---|---|
0, L, LO, LOA, LOAD |
Applied load; EXCITEID references DAREA data. |
1, D, DI, DIS, DISP |
Enforced displacement; EXCITEID references SPCD data. |
2, V, VE, VEL, VELO |
Enforced velocity; EXCITEID references SPCD data. |
3, A, AC, ACC, ACCE |
Enforced acceleration; EXCITEID references SPCD data. |
5. | When EXCITEID refers to an SPCD entry, the modal space will be augmented with displacement vector(s) from linear static analysis with unit prescribed displacement at each of the SPCD degrees-of-freedom. |
6. | All static structural loads can be referenced by EXCITEID by referring to the SID on the structural load. The structural loads are FORCE, FORCE1, FORCE2, MOMENT, MOMENT1, MOMENT2, PLOAD, PLOAD1, PLOAD2, PLOAD4, RFORCE, ACCEL, ACCEL1, ACCEL2 and GRAV. EXCITEID cannot reference the LOAD and LOADADD Bulk Data entries. |
7. | This card is represented as a loadcollector in HyperMesh. |
See Also: