HyperWorks Solvers

CAABSF

CAABSF

Previous topic Next topic Expand/collapse all hidden text  

CAABSF

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

CAABSF – Frequency-dependent Fluid Acoustic Absorber Element

Description

Defines the frequency-dependent fluid acoustic absorber element in coupled fluid-structural analysis.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

CAABSF

EID

PID

G1

G2

G3

G4

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

CAABSF

71

4

1

10

5

 

 

 

 

Field

Contents

EID

Unique element identification number.

No default (Integer > 0)

PID

PAABSF property entry identification number.

No default (Integer > 0)

Gi

Grid point identification numbers of fluid connection points.

Default = blank (Integer > 0 or blank)

Comments

1.If only G1 is specified, a point impedance is assumed. If G1 and G2 are specified, a line impedance is assumed. If G1, G2 and G3 are specified, an impedance is associated with the area of the triangular face. If G1 through G4 are specified, an impedance is associated with the quadrilateral face.
2.The CAABSF element must connect entirely to fluid points on the fluid-structure boundary.
3.This card is represented as a CAABSF element in HyperMesh.

See Also:

Coupled Frequency Response Analysis of Fluid-Structure Models

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function

The Input File