HyperWorks Solvers

DAREA

DAREA

Previous topic Next topic Expand/collapse all hidden text  

DAREA

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

DAREA – Dynamic Load Scale Factor

Description

Defines scale (area) factors for dynamic loads. DAREA is used in conjunction with RLOAD1, RLOAD2, TLOAD1, and TLOAD2 entries.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DAREA

SID

P1

C1

A1

P2

C2

A2

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DAREA

3

64

2

5.7

65

2

5.7

 

 

Field

Contents

SID

Identification number.

No default (Integer > 0)

P1, P2#

Grid or scalar point identification number.

No default (Integer > 0)

C1, C2#

Component number. Component numbers refer to the displacement coordinate system.

No default (Integer 1 through 6, or 0 for scalar points)

A1, A2#

Scale (area) factor.

No default (Real)

Comments

1.One or two scale factors may be defined on a single entry.
2.Refer to RLOAD1, RLOAD2, TLOAD1, or TLOAD2 entries for the formula that define the scale factor A#.
3.When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank when the grid reference is a scalar point (SPOINT), and that the component be > 1 when the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point (SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank; interpreting all of these as 0 for scalar points and as 1 for structural grids. When the component is greater than 1, the grid reference must always be a structural grid (GRID).
4.This card is represented as a constraint load in HyperMesh.

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function

The Input File