HyperWorks Solvers

FATDEF

FATDEF

Previous topic Next topic No expanding text in this topic  

FATDEF

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

FATDEF – Elements for Fatigue Analysis

Description

Defines elements, and associated fatigue properties, for consideration in a fatigue analysis.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

FATDEF

ID

TOPSTR

 

 

 

 

 

 

 

Optional continuation lines for selecting elements, and associated fatigue properties, using element sets (ELSET)

 

ELSET

ELSID1

PFATID1/ PFATSPWID1

ELSID2

PFATID2/PFATSPWID2

ELSID3

PFATID3/PFATSPWID3

 

 

 

 

ELSID4

PFATID4/PFATSPWID4

 

 

 

 

 

 

 

 

 

 

Optional continuation lines for selecting elements and associated fatigue properties through referenced properties (PTYPE)

 

PTYPE

PID1

PFATID1/PFATSPWID1

PID2

PFATID2/PFATSPWID2

PID3

PFATID3/PFATSPWID3

 

 

 

 

PID4

PFATID4/PFATSPWID4

 

 

 

 

 

 

 

 

 

 

Optional continuation lines for seam weld fatigue analysis

 

FATSEAM

FATSEAM ID1

PFATSMW ID1

FATSEAM ID2

PFATSMW ID2

FATSEAM ID3

PFATSMW ID3

 

 

 

 

FATSEAM ID4

PFATSMW ID4

 

 

 

 

 

 

 

 

 

 

Optional continuation lines for excluding elements using element sets (ELSET)

 

XELSET

XELSID1

XELSID2

XELSID3

XELSID4

XELSID5

XELSID6

XELSID7

 

 

 

XELSID8

 

 

 

 

 

 

 

 

 

Optional continuation lines for excluding individual elements

 

XELEM

XEID1

XEID2

XEID3

XEID4

XEID5

XEID6

XEID7

 

 

 

XEID8

 

 

 

 

 

 

 

 

 

 

Field

Contents

ID

Each FATDEF card must have a unique ID. FATDEF Subcase Information entry may reference this ID.

No default (Integer > 0)

TOPSTR

Top stress fraction. Elements with combined stress not in this top fraction of each MATFAT group will be screened out and have no results. This field is ignored in fatigue analysis on a transient subcase.

Default = blank (100% will be used internally), (0.0 < Real < 1.0)

ELSET

Indicates that a list of pairs of ELSET and PFAT/PFATSPW IDs will follow, defining elements, and their associated fatigue properties, for consideration in fatigue analyses where this FATDEF is selected.

ELSID#

Element set ID. Elements in this set will be considered in fatigue analyses where this FATDEF is selected.

No default (Integer > 0)

PFATID#

Fatigue property ID. This is the identification number of a PFAT entry, which indicates the fatigue property used by the preceding elements defined by ELSID# or PID#.

PFATSPWID#

Fatigue property ID for spot weld fatigue analysis. This is the identification number of a PFATSPW entry, which indicates the fatigue property used by the preceding elements defined by ELSID# or PID#.

PTYPE

Indicates that a list of pairs of property IDs of type PTYPE and PFAT/PFATSPW IDs will follow; defining elements and their associated fatigue properties for consideration in fatigue analyses where this FATDEF is selected (Comment 2).

PID#

Property ID. This is the identification number of a property entry corresponding to the specified PTYPE field. Elements referencing any property with this ID will be considered in fatigue analyses where this FATDEF is selected (Comment 3).

No default (Integer > 0)

FATSEAM

Indicates that the list of pairs of FATSEAM ID’s and PFATSMW ID’s are to follow and these will be used for seam weld fatigue analysis.

FATSEAM ID#

References a FATSEAM Bulk Data Entry that contains parameters and property identification information for seam weld fatigue analysis.

PFATSMW ID#

Fatigue property ID for seam weld fatigue analysis. This is the identification number of a PFATSMW entry, which indicates the fatigue property used by the preceding elements defined by ELSID# or PID#.

XELSET

Indicates that IDs of elements sets excluded from fatigue analysis follow.

XELSID#

Element set ID. Elements in these sets will be excluded from fatigue analyses where this FATDEF is selected.

No default (Integer > 0)

XELEM

Indicates that IDs of elements excluded from fatigue analysis follow.

XEID#

Element ID. These elements will be excluded from fatigue analyses where this FATDEF is selected.

No default (Integer > 0)

Comments

1.At least one of the optional continuation lines ELSET or PROP must be present.
2.PTYPE can be set as one of PSHELL, PSOLID, PWELD, PBAR, PBARL, PBEAM, or PBEAML to represent that the corresponding property ID’s (PID# fields) are to follow.
Note:Tthat PWELD, PBAR, PBARL, PBEAM, or PBEAML references for PTYPE field are supported only for spot weld fatigue analysis. Additionally, for spot weld fatigue analysis, PFATSPWID# fields should reference corresponding PFATSPW entries.
3.The PID# field should reference the property entry of the same type as the corresponding PTYPE.
4.This card is represented as a loadcollector in HyperMesh.

See Also:

Fatigue Analysis

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function

The Input File