HyperWorks Solvers

MATF1

MATF1

Previous topic Next topic Expand/collapse all hidden text  

MATF1

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

MATF1 – Isotropic Material Frequency Dependence

Description

Specifies frequency-dependent material properties on MAT1 entry fields via TABLEDi entries.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATF1

MID

T(E)

T(G)

T(NU)

T(RHO)

T(A)

 

T(GE)

 

 

T(ST)

T(SC)

T(SS)

 

 

 

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATF1

17

32

 

 

17

 

 

53

 

Field

Contents

MID

Material property identification number that matches the identification number on the MAT1 entry.

(Integer > 0)

T(E)

A TABLEDi entry identification number for the Young’s modulus.

(Integer > 0 or blank)

T(G)

A TABLEDi entry identification number for the shear modulus.

(Integer > 0 or blank)

T(NU)

A TABLEDi entry identification number for the Poisson’s ratio.

(Integer > 0 or blank)

T(RHO)

A TABLEDi entry identification number for the mass density.

(Integer > 0 or blank)

T(A)

A TABLEDi entry identification number for the thermal expansion coefficient.

(Integer or blank)

T(GE)

A TABLEDi entry identification number for the damping coefficient.

(Integer > 0 or blank)

T(ST)

A TABLEDi entry identification number for the tension stress limit.

(Integer > 0 or blank)

T(SC)

A TABLEDi entry identification number for the compression limit.

(Integer > 0 or blank)

T(SS)

A TABLEDi entry identification number for the shear limit.

(Integer > 0 or blank)

Comments

1.Fields 3, 4, and so on of this entry correspond, field-by-field, to fields 3, 4, and so on of the MAT1 entry referenced in field 2. The value in a particular field of the MAT1 entry is replaced or modified by the table referenced in the corresponding field of this entry. In the example shown, E is modified by TABLEDi 32, RHO is modified by TABLEDi 17 and GE is modified by TABLEDi 53. Blank or zero entries mean that there is no frequency dependence of the field on the MAT1 entry.
2.The MATF1 entries may refer to blank entries on the respective MAT1 card. In this case, they will be applied to default values of respective parameters. Initial values of E, G, or NU will be supplied according to comment 4 on the MAT1 entry.
3.Table references must be present for each item that is frequency dependent. For example, it is not sufficient to only give table references for fields 3 and 4 (Young’s modulus and shear modulus) if density is also frequency dependent.
4.In Modal Frequency Response Analysis, the frequency-dependency is only used in the frequency response part of the solution, not in the modal analysis part of the solution.
5.This card is represented as a material in HyperMesh.

See Also:

Frequency Response Analysis

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function

The Input File