*fatiguewrite
Creates a fatigue analysis input file in the format specified.
Syntax
*fatiguewrite entities markmask filename datagroup filetype analysistype simulationtype sim1 sim2 sim3
Type
HyperMesh Tcl Modify
Description
Creates a fatigue analysis input file in the format specified.
Inputs
- entities
- The entity types on the mark.
- Elements
- Nodes
- markmask
- The mark ID containing the entities.
- filename
- The specified file name into which the fatigue analysis results are written.
- datagroup
- The data group type chosen (depending upon the solver).
- filetype
- The file type.
- BINARY
- ASCII
- analysistype
- The analysis type.
- Linear
- Transient
- simulationtype
- The simulation types.
- 0
- 1
- 2
- sim1
- If simulationtype = 0, writes all simulations for the specified entities.
- sim2
- If simulationtype = 1, writes only the simulation values for a specific simulation.
- sim3
- If simulationtype = 2, writes only the simulations in the specified range, given start and end simulation values.
Example
*fatiguewrite(entities element (entity selected)
markmask 200 (element number(s))
filename c:\temp\fatg, (file name)
datagroup Stress TOP SURFACE
filetype ascii
analysistypelinear
simulationtype 0
sim1 all
sim2 NULL
sim3 NULL
Load the HyperMesh model or solver input data and results files prior to using this command.